¸ðµ¨ : MM-410 Rasterizing Waveform/Vector Monitor
Component, Composite, S-VideoÀÇ ½ÅÈ£¸¦ waveform, vectorscope·Î Ãâ·ÂÇÏ´Â Àü¹®°¡Ç°ÁúÀÇ Àåºñ ³ôÀº »ùÇøµ ºñÀ²°ú 10bitÀÇ ½ÅÈ£ 󸮷ΠCRT ǰÁúÀÇ raster µð½ºÇ÷¹ÀÌ ±¸Çö NTSC, PAL Áö¿ø, EBU, SMPTE, Beta, MII, GBR(WFM only) ÀÔ·Â : Composite, S-Video, Component Ãâ·Â : Standard Picture Monitor Àü¿ø : 100-240 VAC, 50/60 Hz
|
|
Split Screen Display |
|
|
|
Component Vector |
|
Waveform Limit LineRemote Log Book Display |
 |
|
 |
Component Video Parade |
Rasterizing Waveform Monitor/Vectorscope with 10 Bit Digital Precision and Analog CRT Display Quality
An excellent alternative to the analog monochromatic CRT monitors! Magni's patented raster technology with 10 bit signal processing provides accurate waveform and vector displays on a standard color picture monitor. It allows storage of acquired waveforms, with superior display accuracy as the raster-based display is not subject to CRt errors.
The engineer's choice for applications that support multiple formats! The MM-410 Series monitors are dual standard (NTSC and PAL) and multi-format (Beta, MII, S-Video, EBU, GBR). Separate A and B channels provide for easy transition between Composite and Component monitoring. The MM-410 loop through inputs can be configured for: •Two Composite or one Composite and one S-Video •One Composite and one 3 wire Component
For video professionals who need basic monitoring and quality performance! Features include a unique split screen mode, providing picture, waveform, and vector on a single display. Video operators will appreciate the unique peak video over limit region identified in red. Other features, like the SCH and Blanking graticule, make advanced measurements easy for the experienced engineer. User friendly front panel control and 10 memory presets provide instant set-up recall such as Composite parade of filters or Component waveform parade. Magnification and line select modes, enable viewing of VITS and vertical blanking interval.
An indispensable tool in video production! On-screen read out of SCH phase and color frame indicator. Simultaneous display of both A and B channels provides for easy camera timing and color matching required when: •Setting and balancing camera levels •Checking time base correctors •Assuring color fidelity and timing for editing Its compact 1RU low power design fits the smallest editing suites or ENG vans.
|
|
| The MM-410 Rasterizing Waveform/Vector Monitor |
|
| |
| Component, Composite, and S-Video waveform monitor and vectorscope |
|
| On-screen matric display of picture, waveform and vector |
|
| High equivalent sampling rate and 10 bit signal processing provide precise, CRT-like raster display |
|
Applications Professional quality, general purpose composite waveform monitor and vectorscope conbination for studio and transmission applications |
|
| Affordable Component and Composite video monitoring for multimedia non-linear editing and TV studio production applications. |
|
| Adaptable to DV and SDI monitoring, with an external DV/SDI-to-Component/Composite converter |
|
|
|
On-Screen Menus |
|
Features • Multi-format: Composite, S-Video and 3-wire Component • Multi-standard: NTSC/PAL, 525/625 • Simultaneous Composite and S- Video display outputs for easy routing throughout the facility • Vector display for Composite and 3 wire Component • 100 ns/division horizontal resolution with anti-alias CRT simulation display • Capture and storage of waveform and vector images for signal comparisons • Ten user defined memories simplify monitoring of specific operational settings • Line selector provides bright displays of CITS or individual lines • User-friendly control and interface • Compact one RU package and low power for cost-effective operation |
|
|
|
SCH & Blanking Measurement |
Magni Systems, Inc. has been a leading provider of innovative television test and measurement, and computer graphics-to-video products since 1984. Magni's products provide signal sources and perform monitoring and measuring functions for braodcast stations, cable television, production studios, digital content creators, and video equipment manufacturers worldwide. Magni's technology, innovation and expertise have produced market-leading products which have received two prestigious EMMY awards.
|
| |
Rear Panel Connectors |
| |
|
| |
Specifications |
| |
Electrical VIDEO STANDARDS NTSC and PAL Composite plus S-Video EBU, SMPTE, Beta, MII, GBR (WFM only) Component (525/625)
VIDEO INPUTS Two loop through inputs (input A and B): Input A configurable for Composite or S-Video Input B configurable for 3 wire Component, S- Video or Composite Return loss (75 W) > 40 dB to 6 MHz
EXTERNAL REFERENCE INPUT Composite loop through (NTSC/PAL)
PICTURE MONITOR DISPLAY OUTPUTS Composite and S-Video
DISPLAY Raster scan on-screen display on standard picture monitor Waveform, vector, picture or split screen display of all three
READOUT VITC time code or real time clock (RTC) SCH frame reference
MEMORY Memory: 10 recallable blue key memories to store MM-410 configurations and front panel settings Images: up to 6 recallable waveform/vector images can be stored
WAVEFORM MONITOR Vertical gain accuracy: +/-1% with 1.0V input Vertical MAG: X 2.5 typical Frequency response: +/-1% to 6 MHz, +/-2% to 8 MHz (waveform mode) Low pass filter response: +/-1% of DC at 50 kHz, <-40 dB at fsc Band pass filter response: +/-1% of DC at fsc attenuation of >25 dB at 2xfsc. 1.5 MHz bandwidth Transient response: Pulse to bar ratio: 0.99:1 to 1.01:1 typical Pulse preshoot/ringing: <1% Line time tilt: <1%
|
|
DC Restorer Slow: Typically 12 dB attenuation At 50/60 Hz Fast: >26 dB attenuation At 50/60 Hz Timing difference between channels: +/-5 ns Sweep timing: Accuracy digitally derived Time base: 1H(5µs/div), 2H(10µs/div), 2F Line select: Displays line 1 through line 262/312 MAG Mode: 0.1µs/div (1H), 1.0µs/div (2H), 2F (approximately x25)
VECTORSCOPE Display accuracy Amplitude error: +/-2% Phase error: +/-1.25¡Æ Chroma bandwidth: 700 kHz +/-100 kHz Variable phase: 360 degree Vector MAG: x2.5 typical
INTERFACES Ground closure interface Logic level interface memory recalled for instrument control through memory settings
Mechanical DIMENSIONS One rack unit (1RU) H/W/D: 45 mm (1.75 in) 486 mm (19 in) 432 mm (17 in)
POWER REQUIREMENT Line voltage: 100 to 240 VAC, 50/60 Hz, 50 VA maximum
OPERATING CONDITIONS 0 to 50¡Æ C 90% relative humidity
SAFETY Tested to meet or exceed UL 1950, CSA 1402C, IEC 950 CE certified
|
|
|
|
|
|
|
Bright Vertical Interval Displays |
Quality Anti-Aliased Waveforms |
Filter Parade Display | | | |
|
|
|