ESW 41-S

4°³ÀÇ SDI ÀÔ·ÂÀ» ¹Þ¾Æ ÀԷ¿¡ ¹®Á¦°¡ »ý°åÀ» °æ¿ì Á¤»óÀûÀÎ ½ÅÈ£·Î ½ºÀ§Äª ½ÃÄÑÁÖ´Â Àåºñ
ÀÔ·Â : 4 x SDI
Ãâ·Â : 2 x SDI (Prog, Aux)  
SDI 4x1 Emergency Switch

Seamless LIVE emergency switching
Automatic switching on signal loss
GPI switch control
Clean switching of mis-timed inputs
4x1 emergency switching for SDV

The ESW-41S is designed for applications requiring automatic
emergency switching capability in the event of signal loss. The
main program input in monitored and on loss of sync data, the
output is switched to the next available ¡®good¡¯ input after four
blank frames (or if the user wishes, the output can switch to black).

The automatic switching feature can overridden by the operator through external connection
to the GPI.

The program path is maintained, even in the event of a power failure, through the inbuilt
bypass relay. This connects input 1 to the main output.

Inputs:
4 x Serial Digital Video (270Mb/s) to SMPTE 259M (EBU Tech 3267-E)
1 x Analogue video reference

Outputs:
1 x SDV Program out
1 x SDV Auxiliary output
In the event of power failure to the unit a passive bypass relay connects input 1
to the main program output.

Control:
5 GPI inputs (4 input select, 1 relay bypass enable)

User Adjustments: Timing adjustment and setup
Input select
625/525 line operation select
Reference timing adjustment
Switch to black
Relay bypass (latching push button)
CPU input select enable (for front panel control)

Physical: 1U rack mounting, up to 2 cards per 1U frame

Ordering: ESW41-S
-DM (optional second mains input for redundancy)
-FP (optional front panel control)

Related products: ESW201-B, ESW201-S, RSW204, ASW201, ESW-ASI