ACTIV
4 ~ 8 ´ëÀÇ Analog/Digital VTRÀ» TBCÇØÁÖ´Â Àåºñ. Digital VTRÀÇ ÀÔ/Ãâ·Â ¿Àµð¿À·¹º§ Á¶Á¤°¡´É. ÀÔ·Â : Analog Sync x 4/8, Digital Sync x 4/8 Ãâ·Â : Analog Sync x 4/8, Digital Sync x 4/8
ACTIV |
- VTR/TBC remote parameter controller
-
|
- Activ is the indispensable editing accessory, providing all TBC control functions for both analogue and digital VTRs. It is an invaluable system tool in any installation, and smoothes the integration of analogue and digital islands by eliminating all timing problems.
-
- Activ is designed for both the small and large installation and is equally at home in the edit suite, transmission gallery, duplication bank or OB van. It is available as a single control unit for up to eight sources, but can easily be expanded. The control panel can be separated from the mainframe, simplifying installation wiring. Up to eight control panels can be networked with each mainframe. The latest software will also work with Omnibus edit control systems
-
- Features
-
- • Control of analogue and digital VTRs and TBCs
- • Control of both audio input and output levels for digital VTR's
- • Simple LOCK function to prevent inadvertent adjustment of the system
- • Multiple presets for each VTR/TBC to allow instant recall of set-ups for edit matching
- • Control of four sources per output module, allowing for simple expansion and upgrade
- • Eleven output channels per analogue VTR/TBC, allowing control of additional analogue functions, such as VCA and logical functions, such as Freeze and Bypass
- • 14-bit resolution on all analogue outputs for level stability and accurate system timing
- • Storage of horizontal and subcarrier phase, so that the VTR/TBC can be timed to multiple destinations
- • Local storage of timing at each remote panel, solving routing and timing problems
- • Configuration mode to allow the user to change all soft key labels and display ranges, so Activ can be tailored to the user's VTR types, signal format and language
- • Optional key legends to match actual installation
- • Interfaces to the Omnibus automation system
- • Controls D2, D3, D5, Beta, Digibeta, 1", S-VHS, BVX-10
|
- Technical Information
-
- Power consumption
- Mainframes: 30W @ 240VAC
- Remote panel: 10W @240VAC
-
- Panel dimensions
- Master: 2U rackmount, 196 mm deep
- Remote: 2U rackmount, 196 mm deep
-
- Weight
- Mainframes: 2 kg
- Remote panel: 1.5 kg
-
- Applicable VTRs
- All BVW, BVW and PVW studio VTRs; D-2, D-3, D-5 digital VTRs; M-II studio VTRs; 1" C Format; U-matic VTRs and TBCs; Series 22 S-VHS; VDR-1000 Laser Disc; BVX-10 colour corrector
-
- Ordering Information
- Activ-4: 4 analogue VTRs/TBCs with integral operational panel
- Activ-8: 8 analogue VTRs/TBCs with integral operational panel
- Activ-4S: 4 digital VTR's/TBCs with integral operational panel
- Activ-8S: 8 digital VTRs/TBCs with integral operational panel
- Activ-4/4S: 4 analogue and 4 digital VTRs/TBCs with integral operational panel
- Activ-R: Separate remote control panel
-
- Activ-4X: Expansion rack for additional 4 analogue VTRs/TBCs
- Activ-8X: Expansion rack for additional 8 analogue VTRs/TBCs
- Activ-4SX: Expansion rack for additional 4 digital VTRs/TBCs
- Activ-8SX: Expansion rack for additional 8 digital VTRs/TBCs
- Activ-4/4SX: Expansion rack for additional 4 analogue and 4 digital VTRs/TBCs
-
- System configuration
- The next page shows a typical system configuration for Activ in an edit suite environment.
-
-
|